Function library lenzeiosystem.lib, Function blocks – Lenze DDS Function library IOSystem User Manual

Page 28

Advertising
background image

4.4

L_IOParAlAOModule − Parameterisation function

Function library LenzeIOSystem.lib

Function blocks

4−10

L

LenzeIOSystem.lib EN 1.7

ð Inputs

(Variable type: VAR_INPUT)

Variable name

Data type

Information/possible settings

bExecute

Bool

Execute write request

FALSE

ä TRUE Write request is executed

byNodeAdr

Byte

Device address: 1 − 63

byAnalogModuleNo

Byte

Slot number

·

The first analog module installed is assigned slot number 1.

·

A maximum of 16 analog modules may be plugged.

bEnableDiagnosticAlarm

Bool

Enable diagnostic alarm

TRUE Diagnostic alarm is enabled

bEnableAnalogInterrupt

Bool

Enable analog data transmission

TRUE Data transmission is enabled

byFunctionInput_CH1

...

byFunctionInput_CH2

Byte

Parameterise function

Default ±10V function parameter = 01

h

^ 6−6

bySampleRate_CH1

...

bySampleRate_CH2

Byte

Select number of conversions per second

0 15 conversions

1 30 conversions

2 60 conversions

3 123 conversions

4 168 conversions

5 202 conversions

6 3.7 conversions

7 7.5 conversions

byFunctionOutput_CH3

...

byFunctionOutput_CH4

Byte

Parameterise function

Default ±10V function code = 01

h

^ 6−6