8 l_iossidatatoio - counter function, L_iossidatatoio − counter function, Function library lenzeiosystem.lib – Lenze DDS Function library IOSystem User Manual

Page 62: Function blocks, 8 l_iossidatatoio − counter function

Advertising
background image

5.8

L_IOSSIDataToIO − Counter function

Function library LenzeIOSystem.lib

Function blocks

5−16

L

LenzeIOSystem.lib EN 1.7

5.8

L_IOSSIDataToIO − Counter function

Depending on a comparison value, the two outputs of the module can be set via function block
L_IOSSIDataToIO.

To the outputs, different comparison functions or comparison values can be assigned, which must
be transferred to the SSI module in succession.

L_IOSSIDataToIO

dwSet_Compare

abyPDO_DataToIO

Converter

dw to byte

Byte

0

DI

Byte

2

DI

Byte

3

DI

Byte

1

DI

bControl_SetOut_1

bControl_SetOut_0

bControl_Condition

ð Inputs

(Variable type: VAR_INPUT)

Variable name

Data type

Information/possible settings

bControl_Set_0

Bool

Output 0
Monitor comparison value

0 Off

1 On

bControl_Set_1

Bool

Output 1
Monitor comparison value

0 Off

1 On

bControl_Condition

Bool

Set condition of outputs

0 Actual value > comparison value

1 Actual value < comparison value

dwSet_Compare

Double word

Enter comparison value

Outputs

ð

(Variable type: VAR_OUTPUT)

Identifier

Data type

Value/meaning

abyPDO_DataToIO

Byte array

Interface with the inputs of function blocks L_IOPDO15 or L_IOPDO610 for the
transfer of information from the counter module.

Advertising