5 selecting the counter modes epm-t410, Selecting the counter modes epm−t410, Function library lenzeiosystem.lib – Lenze DDS Function library IOSystem User Manual

Page 80: Appendix, 5 selecting the counter modes epm−t410

Advertising
background image

6.5

Selecting the counter modes EPM−T410

Function library LenzeIOSystem.lib

Appendix

6−10

L

LenzeIOSystem.lib EN 1.7

6.5

Selecting the counter modes EPM−T410

Mode

Function

IN1

IN2

IN3

IN4

IN5

IN6

OUT0

OUT1

Auto

Reload

Compare

Load

[hex]

[dec]

2 counters

0

1

00

h

0

32 bit counter

RES

CLK

DIR

RES

CLK

DIR

·

·

01

h

1

Encoder 1 edge

RES

A

B

RES

A

B

·

·

03

h

3

Encoder 2 edges

RES

A

B

RES

A

B

·

·

05

h

5

Encoder 4 edges

RES

A

B

RES

A

B

·

·

4 counters

0.1

0.2

1.1

1.2

08

h

8

2 × 16 bit counters
(counting direction upwards/upwards)

CLK

CLK

CLK

CLK

09

h

9

2 × 16 bit counters
(counting direction downwards/upwards)

CLK

CLK

CLK

CLK

0A

h

10

2 × 16 bit counters
(counting direction downwards/upwards)

CLK

CLK

CLK

CLK

0B

h

11

2 × 16 bit counters
(counting direction downwards/upwards)

CLK

CLK

CLK

CLK

2 counters

0

1

0C

h

12

2 × 32 bit counters (counting direction
upwards)

RES

CLK

GATE

RES

CLK

GATE

·

·

ü

0D

h

13

2 × 32 bit counters (counting direction
downwards)

RES

CLK

GATE

RES

CLK

GATE

·

·

ü

0E

h

14

2 × 32 bit counters (counting direction
upwards)

RES

CLK

GATE

RES

CLK

GATE

·

·

ь

ь

0F

h

15

2 × 32 bit counters (counting direction
downwards)

RES

CLK

GATE

RES

CLK

GATE

·

·

ь

ь

1 counter

0/1

10

h

16

Frequency measuring

RES

CLK

START

STOP

·

·

ü

11

h

17

Measuring the period

RES

CLK

START

STOP

·

·

ü

12

h

18

Frequency measuring
(output counter runs/stops)

RES

CLK

START

STOP

·

·

ü

13

h

19

Measuring the period
(output counter runs/stops)

RES

CLK

START

STOP

·

·

ü

2 counters

0

1

06

h

6

Measuring the pulse width
(f

ref

50 kHz, counting direction selectable)

RES

PULSE

DIR

RES

PULSE

DIR

14

h

20

Measuring the pulse width
(f

ref

programmable, counting direction

selectable)

RES

PULSE

DIR

RES

PULSE

DIR

15

h

21

Measuring the pulse width
(f

ref

programmable, counting direction

upwards)

RES

PULSE

DIR

RES

PULSE

GATE

16

h

22

Measuring the pulse width
(f

ref

programmable, counting direction

downwards)

RES

PULSE

DIR

RES

PULSE

GATE

2 counters

0

1

17

h

23

2 × 32 bit counters
(counting direction upwards, set function)

RES

CLK

GATE

RES

CLK

GATE

ü

18

h

24

2 × 32 bit counters
(counting direction upwards, set function)

RES

CLK

GATE

RES

CLK

GATE

ü

19

h

25

2 × 32 bit counters
(counting direction upwards, reset function)

RES

CLK

GATE

RES

CLK

GATE

ü

1A

h

26

2 × 32 bit counters
(counting direction upwards, reset function)

RES

CLK

GATE

RES

CLK

GATE

ü

2 counters

0

1

1B

h

27

32 bit counter

G/RES

û

CLK

DIR

G/RES

û

CLK

DIR

·

·

1C

h

28

Encoder 1 edge

G/RES

û

A

B

G/RES

û

A

B

·

·

Advertising