4.8

L_IOParPDO15 − Parameterisation function

Function library LenzeIOSystem.lib

Function blocks

4−20

L

LenzeIOSystem.lib EN 1.7

(Variable type: VAR_INPUT)

ð Inputs
Variable name

Information/possible settings

Data type

wCobID_TxPDO1

...

wCobID_TxPDO5

WORD

Setting identifiers
Default values: input wiring = 0
TxPDO = receive identifiers from the I/O system
Identifiers can be optionally set by value selection.
If the input wiring is "0", the identifiers are composed as follows.
Note!
The basic identifiers are not settled in the pre−assigned area of the standard system
bus.
ID range: 384−831
By this, crossovers of the ID with the free CAN objects which the IO−lib is based on
are avoided.

TxPDOX

Identifier =

Basic ID +

Node address

TxPDO1

838

836

2

TxPDO2

841

TxPDO3

846

TxPDO4

851

TxPDO5

856

byTransmissionType_TxPDO1

...

byTransmissionType_TxPDO5

Byte

Transmission mode

0 Event−controlled

1 Time−controlled

2 Event−controlled with superimposed cycle time

tinhibitTime_TxPDO1

...

tinhibitTime_TxPDO5

Time

Inhibit time: t = 0 − 65535 ms

tCycleTime_TxPDO1

...

tCycleTime_TxPDO5

Time

Cycle time: t = 0 − 65535 ms