2 short overview of the functions, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual
Page 103

1.3 EN - 07/2012
L
103
PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
9400 HighLine - "LAS_40_INTF_Can_94HL_TabPos" sample project
8.4.2
Short overview of the functions
Mode
Description
Automatic
In the automatic mode a sequence runs over an infinite loop.
Selection:
When the drive is referenced...
1.Travel to Position 1,
2.Travel to Position 2,
3.Start at (1.) again.
Manual
In manual mode, the controller can be actuated by setting the individual
control bits manually (Jog1, Jog2, QSP, ErrorReset...). Like this, the controller
can be actuated in manual mode, for instance for cleaning or changing the
tools.
Service
The service mode serves to adjust the controller.
Selection:
• Travel in positive direction for one second,
• Stop for one second,
• Travel in negative direction for one second.
Homing
In the homing mode the drive is referenced.
• Either the home position is set directly, or a homing is started.