Interface assignment in the »Global Drive Control«
[8-38] Assignment of digital inputs DIGIN E1 - E5
[8-39] Assignment of the digital outputs: DIGOUT A1 - A4
[8-40] Assignment of the digital inputs: CAN-IN1 - CAN input block
Terminal 28 (CInh) is to be assigned on
24 V DC.
The assignment of further digital
inputs is not required.
The digital outputs A1 and A2 are LOW
active.
The digital outputs A3 and A4 are HIGH
active.
The following bits of wCtrl are
assigned and connected to the NSET
block:
bCtrl_B00 = xJog1
bCtrl_B01 = xJog2
bCtrl_B02 = xCCw
bCtrl_B04 = not used
bCtrl_B05 = not used
bCtrl_B06 = freely assignable
bCtrl_B07 = freely assignable
bCtrl_B12 = freely assignable
bCtrl_B13 = freely assignable
bCtrl_B14 = freely assignable