8200 vector - "LAS_40_INTF_Can_82_Speed" sample project
8.6.6
Interface assignment in the »Global Drive Control«
[8-32] Assignment of digital inputs DIGIN E1 - E4
[8-33] Assignment of the digital outputs: DIGOUT 1 - digital output A1/A2
[8-34] Assignment of CAN IN1: CAN/FIF-IN1 input block 1
Terminal 28 (CInh) is to be assigned on
24 V DC.
The assignment of further digital
inputs is not required.
Digital output A1 is HIGH active.
The following bits of wCtrl are
assigned and connected to the NSET
block or the DCTRL (Drive Control):
bCtrl_B00 = xJog1
bCtrl_B01 = xJog2
bCtrl_B02 = xCCw
bCtrl_B03 = xQSP
bCtrl_B04 = not used
bCtrl_B05 = not used
bCtrl_B06 = not used
bCtrl_B07 = not used
bCtrl_B08 = free
bCtrl_B09 = xEnable
bCtrl_B10 = xErrorSet
bCtrl_B11 = xErrorReset
bCtrl_B12 = free
bCtrl_B13 = free
bCtrl_B14 = free
bCtrl_B15 = free