PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
9300 - "LAS_40_INTF_Can_93_EP" sample project
210
L
1.3 EN - 07/2012
[8-48] Assignment of the control bits in the 9300 servo inverter
[8-49] Assignment of CAN-OUT1
The following control bits are assigned
fixedly in the drive (control word) and
map the following function:
bCtrl_B03 = xQSP
bCtrl_B08 = not used
bCtrl_B09 = xEnable
bCtrl_B10 = xErrorSet
bCtrl_B11 = xErrorReset
The following bits of STAT are assigned
and connected on CAN-OUT1:
bState_B00 = free
bState_B02 = xQSPActive
bState_B03 = xDriveError
bState_B04 = free
bState_B05 = free
bState_B14 = not used
bState_B15 = xDriveReady
The following status bits are assigned
fixedly in the drive (status word) and
map the following function:
bDCTRL_B06 = xSpeedEqZero
bDCTRL_B07 = xEnable