9300 - "LAS_40_INTF_Can_93_EP" sample project
8.8.6
Interface assignment in the »Global Drive Control«
[8-45] Assignment of digital inputs DIGIN E1 - E5
[8-46] Assignment of the digital outputs: DIGOUT A1 - A4
[8-47] Assignment of the digital inputs: CAN-IN1 - CAN input block
Terminal 28 (CInh) is to be assigned on
24 V DC.
The digital inputs E1- E2 are to be
assigned with H-level. (L -> error QSP
limit active.)
Digital input 4 is assigned with a H-L
edge during homing.
The digital outputs A1 to A4 are HIGH
active.
The following bits of wCtrl are
assigned and connected to the NSET
block:
bCtrl_B00 = xManualPos
bCtrl_B01 = xManualPos
bCtrl_B02 = xHoming
bCtrl_B04 = xStartPRG
bCtrl_B05 = xStopPRG
bCtrl_B06 = xResetPRG
bCtrl_B07 = not used
bCtrl_B12 = program block no.Bit0
bCtrl_B13 = program block no.Bit1
bCtrl_B14 = program block no.Bit2