Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual
Page 166

PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
8200 vector - "LAS_40_INTF_Can_82_Speed" sample project
166
L
1.3 EN - 07/2012
[8-35] Assignment of CAN-Out 1
The CAN monitorings are activated in the project: monitoring time of 3000 ms, "error"
response in the controller.
[8-36] Parameterisation of the 8200 vector in the »Global Drive Control«: Example of setting a "Trip" (C0126) in the controller
The following bits of STAT are assigned
and connected on CAN-OUT1:
bState_B00 = free
bState_B01 = not used
bState_B02 = xQSPActive
bState_B03 = xDriveError
bState_B04 = free
bState_B05 = free
bState_B06 = xSpeedEqZero
bState_B07 = xEnable
bState_B08 = free
bState_B09 = free
bState_B10 = free
bState_B11 = free
bState_B12 = not used
bState_B13 = free
bState_B14 = not used
bState_B15 = xDriveReady