Module, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual
Page 264

PLC Designer V2.x| Lenze Application Samples
The L_SCS_DriveECS.lib library
L_SCS_SupplyModule - actuation of the ECS servo system power supply module
264
L
1.3 EN - 07/2012
13.4.1
Structure of SCS_Control_Supply - actuation to the ECS controller power supply module
Further information on the internal interfaces of the controller can be found in
the Operating instructions (BA) ECSxE_power supply module:
• Section Configuration
Configure system bus | Assignment of the control word
Identifier/data type
Control bits in the
controller
Bit
Identifier
Meaning
xToggleBit
BOOL
0
STE_TOGGLE
Toggle bit
• Bit state change as a sign of life of the
control
xErrorReset
BYTE
1
STE_RESET
TRUE: Reset error
xActivateKSB
BOOL
2
STE_KSB
TRUE: Execute short-circuit braking
xEnableAxis
BOOL
3
STE_CONTROLLE
R ENABLE
TRUE: X6/DO1 is HIGH when the power
supply module is ready for operation
and input X6/DI2 is HIGH.