Capture + tolerances – NTi Audio XL2 Sound Level Meter User Manual

Page 156

Advertising
background image

156

Capture + Tolerances

#AutoStartTrig-
gerLevel

Sets the sound level in dBZ for an automated
level trigger; the passed/failed measurement
starts as soon as the set level e.g. 95 dB is
reached or exceeded. The actual input level
can be monitored at the input range bar. (man-
datory if #AutoStart is True used otherwise
not mandatory)

#AutoStartSet-
tlingTime

Defines the settling time, after the auto start
trigger level is exceeded, until the start of the
measurement; the time is set in 100 millisec-
ond steps e.g. setting 0.5 equals a settling
time of 0.5 seconds. If the input level drops
below the auto start trigger level during this
period, no measurement is carried out. (not
mandatory)

#MeasTime

Defines the measurement time in 100 millisec-
ond steps; e.g. setting 1.5 equals a measure-
ment period of 1.5 seconds. (not mandatory)

Advertising