Correction Value KSET

The correction value page offers a measurement wizard for live
event monitoring, applicable in case the measurement location
differs from the loudest position in the live event area.

Measurement Position

The goal at live event monitoring is to measure the sound level
at the loudest position accessible by the audience. Setting up
any sound level measurement at this loudest location is typi-
cally not practical, thus an alternative measurement position is
chosen. The recommended measurement position in order to
minimize the influence that audience noise has on the mea-
surement:

Mount the measurement microphone in front of the main

speakers
Position the XL2 Analyzer at front of house (FOH)

Connect the XL2 Analyzer and measurement microphone

using a professional audio cable

Positioning the measurement microphone at
front of house (FOH) may result in audience
noise interfering with the measurement results.
The audience noise will be further amplified by
the measured k-values.

Level Difference

Prior to the start of the live event, the level difference between
the loudest and the measurement position is measured. The
XL2 Analyzer calculates the level difference automatically based
on the individual sound level measurements at both locations.
This level difference is included in the sound level reading dur-
ing the live event, and the XL2 thereby displays and records the
sound pressure level of the loudest point.

XL2 positioned at FOH

Loudest

Audience

Position

Level difference

Measurement

Position

(Microphone)

audience area