These levels are shown in the numeric result page:

LAeq5”+k1

Time-averaged sound pressure level LAeq

with correction value k1 and a moving time
window of 5 seconds.

LAeq+k1

Time-averaged sound pressure level LAeq

with correction value k1.

LCpeak+k2

C-weighted peak level LCpeak with correc-

tion value k2.

The following sound levels are displayed in the real-time ana-
lyzer page:

LZFhold3

For tracing of feedback frequencies. The
peak hold time is set to 3 seconds.

LZFlive

Actual real-time spectra.

How to Measure

Select the page

KSET with the rotary wheel .

Measure the correction values k1 and k2 as described in the

chapter Sound Level Meter: Correction Value K

SET

.

Press the start button

.

The icon

LOG flashes during the ongoing measurement. In

the case where the profile #DIN15905-5 & Audio has been
selected the icon AUD flashes, indicating the additional au-
dio wav-file logging.
During the measurement you can monitor the actual sound

level LAeq5”+k1 in order to remain below the permitted lim-

its; alternatively you may monitor the spectrum analyzer for
tracing possible feedback frequencies.
Press stop

to finish the measurement.

In accordance with DIN15905-5, all sound lev-
els are measured, displayed and logged to the
SD Card automatically. The settings are locked,
which ensures that the correct parameters are
measured.
The profile #DIN15905-5 & Audio includes the
recording of Compressed+AGC wav-files.