Sound level meter – NTi Audio XL2 Sound Level Meter User Manual

Page 30

Advertising
background image

30

Sound Level Meter

11

Y-Scale setting

Select the Y-Axis with the rotary wheel

and confirm

with enter .
Select the zoom factor between

20, 10, 5, 2.5 dB/div

and confirm with enter .
Scroll up and down with the rotary wheel

to select the

Y-axis range.
Confirm with enter

.

12

RTA Measurement Result

Real-time analyzer results in 1/1 octave or 1/3 octave band
resolution. Adjust the resolution at

17

.

13

X-Scale setting

Toggles X-scale range between

20 Hz - 20 kHz

RTA levels including wide band results

6.3 Hz - 8 kHz

RTA levels including wide band results

6.3 Hz - 20 kHz

RTA levels

Select the X-Axis with the rotary wheel

and confirm

with enter .
Toggle with the rotary wheel

between the ranges.

Confirm with enter

.

Capture

One of the displayed RTA readings may be captured. Any
measurement data can then be compared with this cap-
tured reference live on the XL2 Analyzer. For example,
compare the RTA spectrum of the left and right speak-
ers.

Select the parameter to be captured

.

Confirm with enter

, to capture the reading.

Select the upper RTA parameter

15

and choose

Capt.
Confirm with enter

.

The lower RTA reading can be compared with the previ-

ously-captured reference data.

10

Measurement Result

Actual level result of the indicated frequency band. The cur-
sor readout displays the center frequency and the level of
the band pointed to by the arrow.

Upper parameter displayed as line.

Lower parameter displayed as bargraph.

Advertising