Warning, Digital inputs, Tou – battery replacement – SATEC PM130 PLUS Manual User Manual

Page 34

Advertising
background image

‎Chapter 2 Installation

I

/ O C O N N E C T I O N S

34

PM130 PLUS Powermeter Series

Digital Inputs

Figure ‎2-25 TOU Digital Input Connection

TOU – Battery Replacement

WARNING!

Only qualified personnel familiar with the instrument and its
associated electrical equipment must perform the RTC battery
backup replacement.

To replace the CR1632 RTC battery:

1. Remove the TOU module from the

PM130 PLUS compartment

2. Open the TOU MODULE case by applying a flat screwdriver at

three snap-in slit (1, 2 and 3), as shown in Figure ‎2-26.

3. Remove the old battery by lifting up the battery holder

retractable tab.

4. Place the new CR1632 battery into the battery holder while

holding up the battery holder retractable tab in such a way that
the (+) battery pole is toward the battery holder, as shown in

Figure ‎2-26.

Advertising