‎Chapter 5 Configuring

T H E P M 1 3 0 P L U S

Configuring

B I L L I N G / T O U

PM130 PLUS Powermeter Series

91

5.4 Configuring Billing/TOU

The TOU battery-backed clock unit is highly recommended in case
of using time-scheduled tariff rates, otherwise a long power
outage may cause the meter clock to lose time so your tariff
counters would not comply with the calendar schedule.

Billing Energy Registers

The PM130E/EH PLUS has 4 fully programmable billing energy registers
that can be linked to any internal energy source or to an external pulse
source that delivers pulses through the meter digital inputs.

Any energy register can provide either a single-tariff energy accumulation
or be individually linked to the TOU system providing both total and multi-
tariff energy billing.

Tariff Rates

The meter tariff structure supports 8 different tariff rates using an
arbitrary tariff schedule. A total of 4 types of days and 4 seasons are
supported with up to eight tariff changes per day.

Maximum Demand Registers

Any of billing energy registers can be individually linked to the maximum
demand register providing the same demand tariff structure as you
selected for energy registers.

Recording Billing Data and Load Profiling

The PM130E/EH PLUS can provide automatic recording of the daily energy
and maximum demand profile to a data log file. Maximum demand
profiling can be individually configured for every register.

See

Factory Preset Data Log Files

in Chapter 5 and

Billing Profile Log File

in Appendix E for more information on the file layout and contents.

To configure the billing registers and the tariff system in your
meter:

1. Link the billing registers to the

respective energy sources.

2. Configure the options for the registers to whether the only

totalization or both total and tariff registers would be used, and
whether daily profiling should be enabled for the energy usage
and maximum demand registers.

3. Configure the daily tariff schedule using the TOU daily profiles

for all types of days and seasons.

4. Configure the season tariff schedule using the TOU calendar.

Configuring Billing/Tariff Registers

To configure the billing/TOU registers in your meter:

1. Select Energy/TOU from the Meter

Setup menu.