Configuring meter security, 3 configuring meter security, Using the front display – SATEC PM130 PLUS Manual User Manual

Page 89

Advertising
background image

‎Chapter 5 Configuring

T H E P M 1 3 0 P L U S

Configuring

M E T E R S E C U R I T Y

PM130 PLUS Powermeter Series

89

Daylight Saving Time

When the daylight saving time is enabled, the meter automatically
advances the device clock by one hour when daylight saving time begins
and puts the clock back one hour when it ends. The default daylight
saving time change points are preset for the U.S.A.

The daylight saving time option is disabled in the PM130 by default. If the
daylight saving time option is disabled, you need to manually adjust the
device clock for daylight saving time.

Time Synchronization Pulses

External time synchronization pulses can be delivered through one of the
digital inputs.

If a digital input is selected as the time synchronization source, the edge
of an external pulse adjusts the device clock at the nearest whole minute.
The time accuracy could be affected by the debounce time of the digital
input, and by the operation delay of the external relay.

5.3 Configuring Meter Security

This setup allows changing the user password and enabling or disabling
password protection.

The password in your meter is preset to 0 at the factory, and password
protection is disabled.

Using the Front Display

Select the AccS entry from the main menu. See

Viewing and Changing

Setup Options

in Chapter 3 for information on configuring parameters via

the front display.

To change the password:

1. Select the PASS entry in the middle

window with the UP and DOWN arrow
buttons.

2. Press the SELECT button to activate the lower window.

3. Use the UP and DOWN arrow buttons to adjust the password.

4. Press ENTER to confirm the new password.

The new password is effective for both the display and
communication ports.

To enable or disable password protection:

1. Select CtrL in the middle window using

the UP and DOWN arrow buttons.

2. Press the SELECT button to activate the lower window.

3. Use the UP and DOWN arrow buttons to select the option.

ON enables password protection and
OFF disables password protection.

4. Press ENTER to confirm your new setting, or ESC to discard

changes.

5. Press ESC to exit the menu.