Connector kp wiring, Connector ka wiring – Rockwell Automation 23P PowerFlex DC Stand Alone Regulator and Gate Amplifier User Manual
Page 23

Rockwell Automation Publication 23P-UM001D-EN-P - July 2012
23
Stand Alone Regulator Installation, Wiring and Configuration
Chapter 2
Connector KP Wiring
• Connect the motor armature terminal C to terminal C on connector KP
• Connect the motor armature terminal D to terminal D on connector KP
Connector KA Wiring
Connector KA must be wired to provide DC voltage feedback to the field
regulator to control the field current based on the armature voltage. Terminal
1A1 is connected internally to terminal C (on connector KP) and terminal 1A2
is connected internally to terminal D (on connector KP). The default
configuration is shown in
and is wired as follows:
• Jumper terminal 1A1 to terminal A1
• Jumper terminal 1A2 to terminal A2
The jumpers will provide the field regulator with the power module/armature
voltage feedback. This is the default wiring scheme for connector KA at the
factory.
Figure 7 - Terminals on Connector KA Jumpered
1A1
(C)
A1 1A2
(D)
A2
Place jumpers between
terminals as shown