Power and ground wiring – Rockwell Automation 23P PowerFlex DC Stand Alone Regulator and Gate Amplifier User Manual

Page 44

Advertising
background image

44

Rockwell Automation Publication 23P-UM001D-EN-P - July 2012

Chapter 3 Gate Amplifier Installation and Wiring

Power and Ground Wiring

Figure 17 - Power and Ground Connections

Table 9 - Terminal Specifications

1

2

3

4

No. Name

Description

Part Number for Customer Plug

(provided with Gate Amplifier)

Wire Size Range

Recommended

Maximum

Minimum

Torque

Input Power
Terminal Block
L1, L2, Ground

Input power - Line
(L1), Neutral (L2)
and Ground

94809302

4.0 mm

2

(10 AWG)

2.5 mm

2

(14 AWG)

0.68 N•m
(6.0 lb•in)

Ground Stud

Chassis Ground

Refer to

Chassis Grounding on page 45

for more information.

External Gate
Power Supply

External Gate
Power Supply
(if used)

94809301

10 AWG, Twisted Pair,
2 Twists / in.

18 AWG, Twisted Pair,
2 Twists / in.

0.68 N•m
(6.0 lb•in)

Ready Relay

Ready Relay Drive
Run Permissive
Interlock

(1)

PN-26501

4.0 mm

2

(10 AWG)

2.50 mm

2

(14 AWG)

0.55 N•m
(5.0 lb•in)

(1) Ready relay contacts are normally open rated at 2 Amps, 120VAC.

1

2

3

4

Advertising