Fwd - gates and rev - gates, 120vac, Power modules. see – Rockwell Automation 23P PowerFlex DC Stand Alone Regulator and Gate Amplifier User Manual
Page 52
Advertising
![background image](/manuals/576844/52/background.png)
52
Rockwell Automation Publication 23P-UM001D-EN-P - July 2012
Chapter 3 Gate Amplifier Installation and Wiring
FWD - GATES and REV - GATES
Four identical forward and four identical reverse gate outputs provide gate signals
for up to four power modules. The output is a burst pattern that has a maximum
amplitude dependent on the gate power supply that is used, internal or external.
The internal “ORing” diode determines whether the internal or external power
supply is used. The maximum gate voltage is 28V with the internal gate supply
and 48V when using the external gate power supply.
120VAC
This is the control power input to the Gate Amplifier. Wire into the cabinet
control power.