39

Stand Alone Regulator Installation, Wiring and Configuration

Chapter 2

Figure 13 - Burden Resistor Jumpers (J4 and J5), Binary Gain Amp DIP Switches

(SW3 and SW4), and External Burden Resistor Terminal Block (XCT) Locations

Figure 14 - Binary Gain Amp DIP Switch to Bit Layout

SW3 SW4

J5 J4

0VI RCT

XCT

MSB

LSB

ON

Off

On

Pulse Transformer Board

Burden Resistor
Jumpers

External Burden Resistor
Terminal Block (XCT)

Binary Gain Amp
DIP Switches

MSB

LSB

Bit 11 Bit 10 Bit 9

Bit 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

IMPORTANT The labels on DIP switches SW3 and SW4 do NOT correspond to the bit

numbers used to set the amplifier gain.

ON

1 2 3 4 1 2 3 4 5 6 7 8

SW3

SW4