Stand Alone Regulator Installation, Wiring and Configuration

Chapter 2

SAR Gate Output Cable

Connect the SAR gate output cable (23PAMP-C

x) to connector KPT11 on the

SAR unit. The opposite end connects to the POWERFLEX DC SAR GATE
INPUT on the Gate Amplifier. See

Chapter 3

Gate Amplifier Installation and

Wiring on page 41

for more information on Gate Amplifier installation and

connections. See

Cable Specifications on page 78

for information on available

cable lengths for the 23PAMP-C

x cable.

Figure 9 - SAR Gate Output Cable Connection (KPT11)

Control Circuit Power

Wiring

The control circuit for the SAR (not identified in the drawings contained in this
manual) must be powered by an external 230V AC or 115V AC, single phase
power supply. This power supply provides power for the SAR cooling fans and a
HIM, communication adapter, I/O, encoder, or DC analog tachometer (if
installed). See “Control Circuit Input Power” in the PowerFlex Digital DC Drive
User Manual, publication

20P-UM001

for details.

In addition, the control circuit power input terminals require short circuit
protection. See “Control Power Protection” in the PowerFlex Digital DC Drive
User Manual, publication

20P-UM001

for details.

1A1

(C)

A1 1A2

(D)

A2

1 2 3 4 5 6 7 8

V1 U1 C1 D1

D C W V U

KPT21

KPT11

KPT31

PE

SAR Gate Output
Cable (KPT11)
Connector

Bottom View of SAR