Gate coupler assembly mounting instructions – Rockwell Automation 23P PowerFlex DC Stand Alone Regulator and Gate Amplifier User Manual

Page 74

Advertising
background image

74

Rockwell Automation Publication 23P-UM001D-EN-P - July 2012

Appendix A Specifications

Gate Coupler Assembly Mounting Instructions

The Gate Coupler Assembly is an open type construction and is intended to be
installed on a flat surface in a suitable enclosure.

• Mount in a clean, dry location. Contamination from oils, corrosive vapors

and abrasive debris must be kept out of the enclosure.

• Mount the unit in a vertical or horizontal position depending on the panel

layout.

• It is permissible to have all gate leads exit from one side of the assembly if

needed, (two pairs per exit port), or one pair of gate leads from each exit
port.

Figure 35 - Minimum Mounting Clearances

Gate Coupler

Assembly

0.75 in.

19 mm

0.75 in.

19 mm

0.75 in.

19 mm

4.5 in.

114 mm

Extra clearance
required at the
input port for
the connector.

Advertising