Rockwell Automation 23P PowerFlex DC Stand Alone Regulator and Gate Amplifier User Manual

Page 49

Advertising
background image

Rockwell Automation Publication 23P-UM001D-EN-P - July 2012

49

Gate Amplifier Installation and Wiring

Chapter 3

Table 11 - Indicators and Control Connection Descriptions

GPS

The +28V Gate power supply provides all of the DC power for the Gate
Amplifier. All other voltages are derived from the +28V Gate power supply. If the
GPS LED is off, all of the other indicating LEDs will also be off. Confirm that
120VAC is present at the power input terminal if the GPS LED is not
illuminated.

LPS

The +5V Logic Power Supply voltage is derived from the +28V Gate power
supply. If the +28V Gate power supply power is not present the logic power
supply LED will not be illuminated.

No. Label on Gate Amplifier

Description

Function

GPS

+28V Gate Power Supply output present LED

This LED is illuminated when the gate power supply output is
present. See

GPS

below for more information.

LPS

+5V Logic Power Supply output present LED

This LED is illuminated when the logic power supply output is
present. See

LPS

below for more information.

GATE FUSE OK

External Power Supply fuse OK LED

This LED is illuminated when the fuse is “OK”. See

GATE FUSE OK

on page 50

for more information.

GATE POWER

Gate power systems OK LED

This LED is illuminated when all onboard systems are functioning
normally. See

GATE POWER on page 50

for more information.

POWERFLEX DC SAR GATE
INPUT

PowerFlex DC Stand Alone Regulator Gate Input

Input for the PowerFlex DC Stand Alone Regulator (SAR) Gates.
See

POWERFLEX DC SAR GATE INPUT on page 50

for more

information.

SD3000 PLUS FWD GATE
INPUT

SD3000

PLUS Forward Gate Input

Input for the SD3000

PLUS forward gates. See

SD3000 PLUS FWD

GATE INPUT on page 50

for more information.

SD3000 PLUS REV GATE
INPUT

SD3000

PLUS Reverse Gate Input

Input for the SD3000

PLUS reverse gates. See

SD3000 PLUS REV

GATE INPUT on page 50

for more information.

RDY

Normally Open relay contacts

Used to indicate that the Gate Amplifier is “ready to run.” See

RDY

on page 51

for more information.

EXT GATE P/S

External Gate Power Supply

This input is used to increase the gate driver level. See

EXT GATE

P/S on page 51

for more information.

FWD - GATES

Armature Forward Gates

Four forward gate outputs to provide gate signals for up to four
power modules. See

FWD - GATES and REV - GATES on page 52

for more information.

REV - GATES

Armature Reverse Gates

Four reverse gate outputs to provide gate signals for up to four
power modules. See

FWD - GATES and REV - GATES on page 52

for more information.

120VAC

Power Input to Gate Amplifier

Cabinet control power. See

120VAC on page 52

for more

information.

1

2

3

4

5

6

7

8

9

Advertising