Gate amplifier, Powerflex dc stand-alone regulator, Gate amplifier 1 of 2 – Rockwell Automation 23P PowerFlex DC Stand Alone Regulator and Gate Amplifier User Manual

Page 55: Gate amplifier 2 of 2

Advertising
background image

Rockwell Automation Publication 23P-UM001D-EN-P - July 2012

55

Gate Amplifier Installation and Wiring

Chapter 3

Figure 22 - Cascading Gate Amplifiers Using the Stand Alone Regulator, Mixed

Configuration

REV Output Cables

SD3K-CBLGSCLIRxxx

+

-

SD3K
FWD IN

SD3K
REV IN

PFDC

Gate Input

FWD

REV

RDY

Ext. P/S

120VAC

Gate Amplifier

FWD Output Cables

SD3K-CBLGSCLIFxxx

To Gate Amplifier,
1 of 2, SD3K-FWD Input

To Gate Amplifier,
2 of 2, SD3K-FWD Input

To Gate Amplifier,
1 of 2, SD3K-REV Input

To Gate Amplifier,
2 of 2, SD3K-REV Input

+

-

SD3K
FWD IN

SD3K
REV IN

PFDC

Gate Input

FWD

REV

RDY

Ext. P/S

120VAC

Gate Amplifier

1 of 2

From Gate Amplifier,

FWD Output

From Gate Amplifier,

REV Output

To Forward

Power Modules

To Reverse

Power Modules

+

-

SD3K
FWD IN

SD3K
REV IN

PFDC

Gate Input

FWD

REV

RDY

Ext. P/S

120VAC

Gate Amplifier

2 of 2

From Gate Amplifier,

FWD Output

From Gate Amplifier,

REV Output

To Forward

Power Modules

To Reverse

Power Modules

To Forward

Power Modules

To Reverse

Power Modules

PowerFlex DC

Stand-alone Regulator

KPT11

(15 Pin D-Shell)

Field Supply
40 A or 70 A

(2 Quad)

To Motor

Field

Gate Cable

Caution: Do NOT use the external power supply (Ext. P/S)
when the gate pulse output is connected to the input of a
“downstream” Gate Amplifier(s). Only use the external power
supply on a final stage Gate Amplifier(s) that provides the
gate pulses to the power module.

C1 D1

D C W V U

1A1 A1 1A2 A2

1 2 3 4 5 6 7 8

KPT31

KA

KP

Power Module

AC / DC

Feedback

Power Module

Armature Voltage

Feedback

Power Module

Thermostat and

CT Feedback

V1 U1

All Terminals are located

on the bottom of the unit.

Advertising