12

2. Secure the Voltage Feedback circuit board to the five standoffs on the control

fame using five large standoffs.

3. Secure the clear plastic shield to the mounting plate to the Voltage Feedback

circuit board using four screws.

4. Connect the feedback cables to sockets J1 and J2 of the Voltage Feedback

circuit board.

Important: Minimum inside bend radius for fiber-optic cable is 25.4 mm (1

in.). Any bends with a shorter inside radius can permanently
damage the fiber-optic cable. Signal attenuation increases with
decreased inside bend radii.

5. Carefully connect fiber-optic cable 9 to socket J4 and fiber-optic cable 8 to

socket J5 of the Voltage Feedback circuit board.

Shield

Screws (4)

Stand-offs (5)

J2

J1

J4

J5

=

!

ATTENTION: Hazard of permanent eye damage exists when using
optical transmission equipment. This product emits intense light and
invisible radiation. Do not look into fiber-optic ports or fiber-optic
cable connectors.