Rockwell Automation 20D PowerFlex 700H to 700S Phase II Control Conversion (Frames 9...14) User Manual

Page 37

Advertising
background image

37

Publication 20C-IN001D-EN-P

Important: Minimum inside bend radius for fiber-optic cable is 25.4 mm (1

in.). Any bends with a shorter inside radius can permanently
damage the fiber-optic cable. Signal attenuation increases with
decreased inside bend radii.

5. Carefully connect the ribbon cable from P1 on the Main Control circuit

board to J2 on the High Power Fiber Optic Interface circuit board and ribbon
cable P2 on the Main Control circuit board to J1 on the High Power Fiber
Optic Interface circuit board.

6. Make the following connections on the High Power Fiber Optic Interface

circuit board:

LED cable to J16

DPI cable to J4

24V Auxiliary Power Supply cable to J15

7. Install all other connections on the 700S Phase II Main Control assembly.

Fiber-Optic

Sockets

J17

J2

J1

J16

J4

J15

J5

Frame 10, 11 and 13

High Power Fiber Optic

Interface circuit board

shown.

=

Advertising