36

Step 6: Installing the High
Power Fiber Optic Interface
Circuit Board

1. Secure the five standoffs to the back side of the 700S control mounting plate.

2. Secure the High Power Fiber Optic Interface board to the standoffs using five

screws.

3. Connect the 10 conductor ribbon cable from P6 on the Main Control circuit

board to J17 on the High Power Fiber Optic Interface circuit board (see
illustration on the following page for location).

4. Carefully connect the fiber-optic cables from the ASIC circuit board to the

fiber-optic sockets on the High Power Fiber Optic Interface circuit board.

!

ATTENTION: Hazard of permanent eye damage exists when using
optical transmission equipment. This product emits intense light and
invisible radiation. Do not look into fiber-optic ports or fiber-optic
cable connectors.

Note: 700S Phase II Control assembly

not shown for clarity only

Install five screws

Frame 10, 11 and 13

High Power Fiber Optic

Interface board shown.

=