Publication 20C-IN001D-EN-P

40

Frame 12 and 14 Size Drives

1. Secure the four standoffs to the front of the EMI Shield.

2. Secure the 24V Common Mode Filter circuit board to the four standoffs on

the EMI Shield using the four screws provided.

3. Connect the 24V Supply cable from connector J8 on the Voltage Feedback

board to connector J5 on the Common Mode Filter board.

4. Connect the twisted pair wires from connector J1 on the Common Mode

Filter board to connector J5 on the High Power Star Interface board.

Step 8: Connecting I/O and
Communications

Refer to publication 20D-AT001…, PowerFlex 700S Conversion Guide - Phase
I to Phase II
, for information about connecting I/O wiring. This publication also
contains information regarding the compatibility of older feedback and
communications options with the new Phase II drive.

24V Supply

cable to J8 on

Voltage

Feedback board

J1

J5

To J5 on the High

Power Star

Interface board

Four screws

=