Common services, Devicenet object, Class code 0x03 – Rockwell Automation 825-MDN Smart Motor Manager DeviceNet Communication Card User Manual User Manual

Page 26: Class attributes, Number of instances: 1, Instance attributes

Advertising
background image

Publication 825-UM002A-EN-P - December 2000

A-4

Common Services

DeviceNet Object

Class Code 0x03

Class Attributes

Number of Instances: 1

Instance Attributes

➊Allocation_byte

Bit 0

Explicit Messaging

Bit 1

Polled I/O

Service Code

Implemented for:

Service Name

Class

Instance

0x0E

Yes

Yes

Get_Attribute_Single

Attribute ID

Access Rule

Name (param #)

Data Type

Value

1

Get

Revision

UINT

2

Attribute ID Access Rule

Name (param #)

Data Type

Value

1 Get

Node

Address

(#151)

USINT

0…63

2

Get

Baud Rate (#152)

USINT

0=125K
1=250K
2=500K

3

Get

BOI

BOOL

0=Not Set
1=Set

5

Get

Allocation Info
Allocation Choice
Master Node Addr

Structure of:
BYTE
USINT

Allocation_byte

0…63 = address