Instance 1 attributes, Instance 2 attributes, Instance 3 attributes – Rockwell Automation 825-MDN Smart Motor Manager DeviceNet Communication Card User Manual User Manual

Page 48: Instance 4 attributes, Instance 5 attributes

Advertising
background image

Publication 825-UM002A-EN-P - December 2000

A-26

Instance 1 Attributes

Instance 2 Attributes

Instance 3 Attributes

Instance 4 Attributes

Instance 5 Attributes

Attribute ID

Access

Rule

Name

Data Type

Value

1

Get

Group Name String

SHORT_STRING

“Main Values”

2

Get

Number of Members

UINT

4

3-6

Get

Parameter Numbers

UINT

1, 3, 4, 5

Attribute ID Access Rule

Name

Data Type

Value

1

Get

Group Name String

SHORT_STRING

“Prot. Values”

2

Get

Number of Members

UINT

5

3-7

Get

Parameter Numbers

UINT

2, 6, 7, 8, 9

Attribute ID Access Rule

Name

Data Type

Value

1

Get

Group Name String

SHORT_STRING

“Sensor
Values”

2

Get

Number of Members

UINT

8

3-10

Get

Parameter Numbers

UINT

10,11,12,13,14
,15,16,17

Attribute ID Access Rule

Name

Data Type

Value

1

Get

Group Name String

SHORT_STRING

“Faults”

2

Get

Number of Members

UINT

7

3-9

Get

Parameter Numbers

UINT

18,180,181,182,
183,184,213

Attribute ID Access Rule

Name

Data Type

Value

1

Get

Group Name String

SHORT_STRING

“Warnings”

2

Get

Number of Members

UINT

2

3-4

Get

Parameter Numbers

UINT

19, 214

Advertising
This manual is related to the following products: