Common services – Rockwell Automation 825-MDN Smart Motor Manager DeviceNet Communication Card User Manual User Manual

Page 34

Advertising
background image

Publication 825-UM002A-EN-P - December 2000

A-12

Instance 4 and 5 Attributes (Group 3 Message Connections)

Common Services

Attribute

ID

Access

Rule

Name

Data Type

Value

1

Get

State

USINT

0=nonexistant
1=configuring
3=established
4=timed out

2

Get

Instance Type

USINT

0=Explicit Message

3

Get

Transport Class Trigger

USINT

0x83 - Server, Transport
Class 3

4

Get

Produced Connection ID

UINT

11???xxxxxx
xxxxxx=source MAC ID

5

Get

Consumed Connection ID

UINT

11???xxxxxx
xxxxxx=source MAC ID

6

Get

Initial Comm Characteristics

USINT

0x21

7

Get

Produced Connection Size

UINT

0xFF

8

Get

Consumed Connection Size

UINT

0xFF

9

Get/Set

Expected Packet Rate

UINT

Set by Master (2500)

12

Get

Watchdog Action

USINT

01

13

Get

Produced Connection Path
Length

UINT

# of bytes in produced
connection path (00)

14

Get

Produced Connection Path

Empty

15

Get

Consumed Connection Path
Length

UINT

# of bytes in consumed
connection path (00)

16

Get

Consumed Connection Path

Empty

Service Code

Implemented for:

Service Name

Class

Instance

0x05

No

Yes

Reset

0x0E

Yes

Yes

Get_Attribute_Single

0x10

No

Yes

Set_Attribute_Single

0x09

Yes

Yes

Delete

0x0D

No

Yes

Apply_Attributes

Advertising
This manual is related to the following products: