PowerFlex 755 IP00, NEMA/UL Open Type Drive

Terminal Block Specifications

TB1 Terminal Designations

Hardware Enable Circuitry

Digital Input 0 can be used as a general purpose programmable input, or by
removal of a jumper, configured as a dedicated hardware enable, which is
unaffected by parameter settings.

To configure Digital Input 0 as a dedicated hardware enable, complete the
following steps.

1.

Access the Control Pod.

2.

Locate and remove the ENABLE Jumper on the Main Control Board (see

page 60

).

Fiber Interface Board

Name

Wire Size Range

Torque

Strip
Length

Maximum

Minimum

Maximum

Recommended

Main Control Board - TB1

2.5 mm

2

(14 AWG)

0.3 mm

2

(28 AWG)

0.25 N•m
(2.2 lb•in)

0.2 N•m
(1.8 lb•in)

6 mm
(0.24 in.)

Fixed I/O

Terminal

Name

Description

Di 0ac

Digital Input 0 (120V AC)

Connections for AC power supply.

Di C

Digital Input Common

Digital input common

Di 0dc

Digital Input 0 (24V DC)

Connections for DC power supply.

+24V

+24 Volt Power

Connections for drive supplied 24V power. 150
mA maximum

24VC

24 Volt Common

Di 0ac

Di C

Di 0dc

+24V

24VC