Input Mode Jumpers

I/O Option Module Terminal Block Specifications

20-750-2262C-2R (24 Volts DC)
20-750-2263C-1R2T (24 Volts DC)
20-750-2262D-2R (120 Volts AC)

ATTENTION: Risk of equipment damage exists. Ensure that the correct voltage
is applied to the I/O Module digital inputs. Refer to the I/O Module catalog
number to determine the voltage rating.

20-750-2262C-2R is rated 24 Volts DC
20-750-2262C-1R2T is rated 24 Volts DC
20-750-2262D-2R is rated 120 Volts AC

Jumper
Position

Voltage Mode

Current Mode

Name

Wire Size Range

Torque

Strip
Length

Maximum

Minimum

Maximum

Recommended

I/O Module TB1

2.5 mm

2

(14 AWG)

0.3 mm

2

(28 AWG)

0.25 N•m
(2.2 lb•in)

0.2 N•m
(1.8 lb•in)

6 mm
(0.24 in.)

I/O Module TB2

4.0 mm

2

(12 AWG)

0.25 mm

2

(24 AWG)

0.5 N•m
(4.4 lb•in)

0.4 N•m
(3.5 lb•in)

7 mm
(0.28 in.)

Ai0

Ai1

Ai0

Ai1

Advertising