Rockwell Automation 1756-HYD02 ControlLogix Hydraulic Servo Module User Manual
Page 51
![background image](/manuals/579309/51/background.png)
Publication 1756-UM525A-EN-P - June 2003
51
Using the 1756-HYD02 Module Features Chapter 4
EXAMPLE
In the following scenario, Disable Keying allows I/O
communication:
• The module configuration is for a 1756-IA16 digital input module.
The physical module is a 1756-IB16 digital input module. In this
case, communication is allowed because the two digital modules
share common data formats.
IMPORTANT
Changing electronic keying selections online may cause the I/O
communication connection to the module to be disrupted and may
result in a loss of data.
Module Configuration
Vendor = Allen-Bradley
Product Type = Digital Input
Module
Catalog Number = 1756-IA16
Major Revision = 2
Minor Revision = 1
Physical Module
Vendor = Allen-Bradley
Product Type = Digital Input
Module
Catalog Number = 1756-IB16
Major Revision = 3
Minor Revision = 2
Communication is allowed