Publication 1794-UM061A-EN-P - July 2006

48 Configure FLEX I/O Digital Modules on a DeviceNet Network

Add the Scanner to the I/O

Configuration of the

Controller Using RSLogix

5000 Software

To access the data of your network, add the scanner to the I/O configuration
of the controller.

To add a scanner:

If You Need to Conserve EtherNet/IP or ControlNet Network
Bandwidth

The default configuration of the scanner gives you the maximum amount of
input, output, and status data.

If the scanner communicates with the controller via an EtherNet/IP or
ControlNet network and you need to conserve bandwidth over that network,
consider reducing the input, output, or status sizes.

• Set the input and output sizes = the number of input and output DINTs

in the scanner that actually store device data.

• If you are

not

going to use all the status information, set the status size

to the minimum required. See Set the status size for a scanner on
page 49.

Step:

See page:

If You Need to Conserve EtherNet/IP or ControlNet Network

Bandwidth

48

Add the Scanner to the I/O Configuration Folder

50

Define the Properties of the Scanner

51

EXAMPLE

Set the status size for a scanner

• If you want to

only

use the ASCII representation of

scanner status/display, then set the Status Size = 10.

• If you also want to read the status code of the scanner,

set the Status Size = 11.