Rockwell Automation 2100-ENET CENTERLINE 2100 Motor Control Centers EtherNet/IP Network Adapter User Manual

Page 37

Advertising
background image

Rockwell Automation Publication 2100-UM006A-EN-P - July 2013

37

Configure the I/O

Chapter 4

6.

Enter the IP address of the E3 Plus EtherNet/IP network adapter.

IP Address

7.

Click Next.

8.

Enter a value for the time between each scan of the adapter.

9.

Make sure Inhibit Module is not checked.

Module Properties

Bit

Contents

0

OutA

1

OutB

2

Fault Reset

3

Not Used

4

Not Used

5

Remote Reset

6

Not Used

7

Not Used

Byte Size

Contents

2 Bytes

Header information (Pad Word)

2 Bytes

Header information (Pad Word)

2 Bytes

Value of parameter pointed to by parameter #61

2 Bytes

Value of parameter pointed to by parameter #62

2 Bytes

Value of parameter pointed to by parameter #63

2 Bytes

Value of parameter pointed to by parameter #64