Overview of the DL40 Plus
Publication 2706-6.2
Adjustable Parameters for Serial Communications
With the DL40 Plus, you can configure RS-232 or RS-485 port
parameters as needed for compatibility with PLCs/SLCs, printers,
slave displays, or control computers.
Serial Communication Parameters
Settings
Baud Rate
300, 1200, 2400, 4800, 9600, 19200
Parity
Odd, Even, No Parity
Handshake
Software, Hardware, None
Data Bits per Character
7 or 8
Null Count
0 to 255
Allows you send a string of nulls to the printer
between characters. Useful with slow printers
that drop characters because they can’t keep
up with normal DL40 Plus output.
Page With
20 –132 characters
Useful for narrow width printer devices.