Creating Message Files

Publication 2706-6.2

Notes

Important: The communications parameter settings selected here
must match the communications settings of the device that is
connected to the DL40 Message Display.

The following lists communications parameters and the choices
available for each. Refer to the DL40 Plus user manual (Publication
2706-6.1) for more information on setting RS-232 or RS-485 ports.

RS-232 Port Settings

The following settings are available from this menu item.
The default value appears in bold.

Parameter

Available choices

Baud Rate

300, 1200, 2400, 4800, 9600, 19200

Data Bits

7 or 8

Parity

None, Odd, Even

Handshaking

None, Software, Hardware

Port Use

DL40 Programmer, DL Slaves, Devices
Using Open Protocol

RS-485 Port Settings

The following settings are available from this menu item. The
default value appears in bold.

Parameter

Available choices

Baud Rate

300, 1200, 2400, 4800, 9600, 19200

Data Bits

7 or 8

Parity

None, Odd, Even

Port Use

DL40 Programmer, DL Slaves, Devices
Using Open Protocol

➀ This setting should always be 8 if Port Use is set to Programmer.

➁ This setting should always be None if Port Use is set to Programmer.

Important: Do not set Port Usage to DL Slaves or Devices Using
Open Protocol if downloading message files to the DL40 through the
RS-485 Port.

RS-232 Printer Settings

These are the settings of the RS-232 Port when the Print Stack or
Print Mode function is active. The following settings are available
from this menu.

Parameter

Available choices

Null Count

0 to 255

Width

20 to 132