4–38

Creating Message Files

Publication 2706-6.2

RS-232 Tape Recorder Settings

Note that RS-232 Tape Recorder Settings

are valid only when

writing to or reading from a tape drive, and that communications to a
tape recorder can be made only via the RS-232 port.

Baud rate is the only modifiable parameter applicable while using a
tape recorder. Your choices are listed below. The default value
appears in bold.

Parameter

Available choices

Baud Rate

300, 1200, 2400, 4800, 9600

This setting will revert to normal RS-232 Port settings (described
above) when the Tape function is finished.

Triggering Port Settings

The parameters presented here will differ between Remote I/O and
Parallel Port versions of the DL40 Message Display. The following
settings are available from this menu item on Remote I/O units. The
default value appears in bold.

Parameter

Available choices

Message Format

Binary, BCD

Variable Format

Binary, BCD

Control-W Format

BCD, ASCII

Bit Trigger Priority Section
Size

0 to 31 words

Always Send Clock Data

Yes or No

➀ If selection is Yes, only clock data will be returned to a PLC no matter what

attributes are set or what data is requested.

The following settings are available from this menu item on Parallel
Port units. The default value appears in bold.

Parameter

Available choices

Message Format

Binary, BCD

Variable Format

Binary, BCD

Control-W Format

BCD, ASCII

High True Logic

Yes or No

Using AC/DC Converter

Yes or No

Data Hold Time

40 to 255 msec

or 10 to 255 msec

➀ If using AC/DC Converter

➁ If not using AC/DC Converter