PERFORMANCE DATA — 548F

COOLING CAPACITIES

548F036 (3 TONS)

Temp (F)

Outdoor

Entering Air

(Edb)

Indoor Entering Air — Cfm/BF

900/0.10

1200/0.15

1500/0.21

Indoor Entering Air — Ewb (F)

72

67

62

72

67

62

72

67

62

75

TC

42.4

39.9

36.5

43.0

41.2

38.7

45.1

42.8

40.3

SHC

16.7

22.0

26.8

17.5

24.2

30.9

19.3

26.9

34.1

kW

2.77

2.71

2.62

2.78

2.74

2.68

2.85

2.79

2.73

85

TC

41.5

38.4

34.8

43.3

40.4

37.0

44.0

41.7

38.7

SHC

16.6

21.6

26.2

18.2

24.6

30.3

19.3

27.2

33.7

kW

3.01

2.92

2.80

3.07

2.98

2.88

3.09

3.03

2.94

95

TC

40.0

36.3

33.0

42.3

38.5

35.2

43.4

40.0

36.7

SHC

16.2

20.9

25.7

18.2

24.2

29.8

19.7

27.2

32.7

kW

3.24

3.10

2.99

3.32

3.19

3.07

3.36

3.24

3.13

105

TC

38.4

34.7

31.0

40.0

36.7

33.1

41.2

37.7

35.2

SHC

15.7

20.5

24.8

17.5

23.9

28.8

19.3

26.6

31.7

kW

3.47

3.32

3.16

3.53

3.41

3.26

3.58

3.44

3.35

115

TC

36.1

32.5

28.9

38.1

34.3

31.1

39.3

35.5

33.2

SHC

15.1

19.8

23.9

17.2

23.2

27.8

19.1

26.2

30.2

kW

3.66

3.50

3.32

3.76

3.59

3.44

3.81

3.65

3.54

125

TC

34.2

30.5

26.8

35.9

32.0

29.3

36.8

33.0

31.3

SHC

14.6

19.2

22.9

16.7

22.6

26.3

18.5

25.5

28.4

kW

3.88

3.68

3.49

3.97

3.77

3.62

4.02

3.83

3.74

548F048 (4 TONS)

Temp (F)

Outdoor

Entering Air

(Edb)

Indoor Entering Air — Cfm/BF

1200/0.11

1600/0.15

2000/0.22

Indoor Entering Air — Ewb (F)

72

67

62

72

67

62

72

67

62

75

TC

55.5

51.9

47.4

56.9

54.6

50.3

59.3

56.5

52.1

SHC

24.5

31.2

37.4

26.0

35.2

43.4

28.4

39.0

47.6

kW

3.80

3.70

3.55

3.84

3.79

3.66

3.93

3.86

3.71

85

TC

53.4

49.7

45.3

56.3

52.6

47.8

57.5

54.1

49.8

SHC

23.8

30.4

36.7

26.3

34.9

42.6

28.3

38.6

46.9

kW

4.10

3.99

3.84

4.23

4.11

3.94

4.27

4.16

4.01

95

TC

52.0

47.4

43.0

53.7

49.9

45.5

54.5

51.6

47.4

SHC

23.4

29.6

35.8

25.5

33.9

41.6

27.3

38.2

45.2

kW

4.47

4.28

4.11

4.53

4.39

4.23

4.56

4.48

4.29

105

TC

49.3

45.0

40.6

51.8

47.2

43.0

52.6

48.7

45.4

SHC

22.5

28.8

34.7

25.3

33.0

40.3

27.1

37.1

43.3

kW

4.77

4.59

4.39

4.90

4.68

4.52

4.92

4.76

4.63

115

TC

46.6

42.4

38.0

48.8

44.6

40.6

50.2

45.8

43.2

SHC

21.7

27.9

33.6

24.3

32.4

38.7

26.8

36.1

41.2

kW

5.08

4.90

4.66

5.21

5.01

4.81

5.29

5.06

4.96

125

TC

44.0

39.6

35.4

45.6

41.6

38.3

47.0

42.9

40.9

SHC

20.9

26.9

32.4

23.3

31.6

36.5

25.9

35.6

39.0

kW

5.45

5.21

4.96

5.51

5.34

5.14

5.60

5.41

5.30

548F060 (5 TONS)

Temp (F)

Outdoor

Entering Air

(Edb)

Indoor Entering Air — Cfm/BF

1500/0.05

2000/0.08

2500/0.14

Indoor Entering Air — Ewb (F)

72

67

62

72

67

62

72

67

62

75

TC

69.3

64.5

59.3

70.8

67.9

62.8

72.9

69.3

65.4

SHC

30.9

39.2

47.4

33.1

44.9

55.4

35.8

49.4

61.4

kW

4.28

4.15

4.03

4.32

4.25

4.12

4.38

4.29

4.19

85

TC

67.7

62.4

56.8

69.1

65.7

60.2

71.1

67.7

63.2

SHC

30.4

38.6

46.5

32.8

44.6

54.4

35.8

50.0

59.8

kW

4.76

4.61

4.49

4.79

4.72

4.56

4.86

4.78

4.65

95

TC

65.2

59.8

54.4

67.7

62.9

57.6

69.1

64.8

60.7

SHC

29.6

37.6

45.5

32.8

43.6

53.2

35.6

49.3

57.7

kW

5.27

5.10

4.97

5.35

5.20

5.07

5.39

5.27

5.14

105

TC

62.3

57.2

51.8

65.1

59.6

54.9

66.8

61.7

58.3

SHC

28.6

33.8

44.4

32.1

42.6

51.6

35.4

48.2

55.5

kW

5.79

5.66

5.50

5.90

5.73

5.61

5.97

5.79

5.68

115

TC

59.7

54.2

49.0

61.7

57.0

52.5

63.2

58.4

55.8

SHC

27.6

35.8

43.2

31.1

41.9

49.6

34.3

47.0

53.2

kW

6.37

6.24

6.06

6.47

6.34

6.20

6.53

6.36

6.31

125

TC

56.5

51.0

46.0

58.2

53.5

49.8

59.4

55.1

53.0

SHC

26.8

34.7

41.9

30.0

40.8

47.3

33.0

46.5

50.5

kW

7.03

6.87

6.65

7.07

6.96

6.82

7.13

7.03

6.96

LEGEND

NOTES:

1. Direct interpolation is permissible. Do

not extrapolate.

2. The following formulas may be used:

t

lwb

= Wet-bulb temperature corre-

sponding to enthalpy of air
leaving indoor coil (h

lwb

)

Where: h

ewb

= Enthalpy of air enter-

ing evaporator coil

3. The SHC is based on 80 F edb tem-

perature of air entering indoor coil.
Below 80 F edb, subtract (corr factor
x cfm) from SHC.
Above 80 F edb, add (corr factor x
cfm) to SHC.

BF

Bypass Factor

Edb — Entering Dry-Bulb
Ewb — Entering Wet-Bulb
kW

Compressor Motor Power Input

Ldb — Leaving Dry-Bulb
Lwb — Leaving Wet-Bulb
SHC — Sensible Heat Capacity

(1000 Btuh) Gross

TC

Total Capacity (1000 Btuh) Gross

t

ldb

= t

edb

sensible capacity (Btuh)

1.10 x cfm

h

lwb

= h

ewb

total capacity (Btuh)

4.5 x cfm

548F

Advertising
This manual is related to the following products: