Maintenance and repairs – Banner SureCross DX80 Wireless Networks User Manual

Page 75

Advertising
background image

75

Banner Engineering Corp. • Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

SureCross Wireless Network

Product Manual

Maintenance and Repairs

DX99...B FlexPower Nodes with Metal Housing

To replace the lithium “D” cell battery in the device,

1. Unscrew the lid on the back side of the metal enclosure.
2. Remove the discharged battery and replace with a new battery. Only use a 3.6V lithium

battery from Xeno, model number XL-205F.

3. Verify the battery’s positive and negative terminals align to the positive and negative

terminals of the battery holder mounted within the case. The negative end is toward the
spring. Caution: There is a risk of explosion if the replacement battery is incorrect.

4. Screw on the lid and tighten.
5. After replacing the battery, allow up to 60 seconds for the device to power up.

When removing the battery, press the battery towards the negative terminal to compress the
spring. Pry up on the battery’s positive end to remove from the battery holder. Properly dispose of
your used battery according to local regulations by taking it to a hazardous waste collection site,
an e-waste disposal center, or other facility qualified to accept lithium batteries.
As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or expose
them to high temperatures. Do not recharge, crush, disassemble, or expose the contents to water.
Replacement battery model number: BWA-BATT-001. For pricing and availability, contact Banner
Engineering.

Warning: Explosions may result in death or serious injury. Do not remove the instrument cover or open the wiring
housing in explosive atmospheres when power and communications are on. Remove the battery-powered device from
the hazardous location before opening the cover and replacing the battery.
Warning: The replacement battery MUST be a Banner approved battery, model number BWA-BATT-001. Use of a
different battery will VOID the intrinsic safety rating of this device and may result in an explosion!
Warning: When replacing the battery, the negative end of the battery holder is the side with the spring terminal. This
side is marked with a minus (−) sign.
Warning: Do not attempt to recharge the battery. These batteries are not rechargeable. Recharging may cause serious
injury to personnel or damage the equipment. Replace only with factory recommended batteries.

Advertising