Finger meter maintenance, Finger set installation instructions, Installation steps – Great Plains 2510HDP Operator Manual User Manual

Page 112: Annual maintenance, Precautions

Advertising
background image

108

1510HDP/2010HDP/2510HDP

Table of Contents

Index

Great Plains Manufacturing, Inc.

118-245M

Table of Contents

Index

2013-10-21

Finger Meter Maintenance

Finger Set Installation Instructions

Installation Steps
Great Plains recommends having the meter service per-
formed by a recognized professional repair facility, such
as a certified Meter Max representative. Improper servic-
ing will result in reduced meter performance.

If you choose to service them yourself, follow these pro-
cedures when installing the finger sets.

Refer to Figure 112

11. Be sure the belt is oriented as shown in Figure 112.

12. Slide the finger set over the shaft and rotate clock-

wise until it sits against the backing plate.

Note: You will hear a click.

13. Firmly press the finger set against the backing plate

while tightening the nut.

14. Tighten the nut until contact is made between the nut

and the finger set. Turn

1

4

to

1

2

flat (

1

24

to

1

12

of a

turn) (a flat is one of the six sides of the nut) after
contact is made. This equals about four inch- pounds
of torque on the nut.

15. Place the slotted nut cover on and carefully align the

slotted nut cover with the shaft hole. Insert the cotter
pin.

16. Rotate the finger set clockwise and make sure the

fingers open and close properly. Fingers should be
closed at the 8:00 to 2:00 position (exit hole) and
open at the 2:00 to 8:00 position.

Annual Maintenance
Finger sets should be inspected on an annual basis.
After cleaning, carefully inspect the fingers and springs
for wear or other abnormalities that may develop. Exces-
sive wear may disrupt singulation performance.

Precautions
1.

Make sure the finger set is properly torqued against
the backing plate. Improperly torqued finger sets
may disrupt seed singulation.

2.

Avoid seed treatments, additives, and other chemi-
cals when possible. They can cause meter perfor-
mance problems, premature wear to meter parts,
and may cause undesired chemical reaction or dete-
rioration to the finger sets. Always use Precision
Planting or Great Plains graphite when using seed
treatments. See “Seed Lubricants” on page 29.
Graphite from other sources may cause premature
wear.

3.

Always pay attention to your seed monitor, pay atten-
tion to your operating manual, and monitor the
amount of seed you are planting compared to your
expectations. Always investigate abnormalities!

Figure 112

Finger Pickup Meter

22507

Advertising