Great Plains 2510HDP Operator Manual User Manual

Page 76

Advertising
background image

72

1510HDP/2010HDP/2510HDP

Table of Contents

Index

Great Plains Manufacturing, Inc.

118-245M

Table of Contents

Index

2013-10-21

Refer to Figure 77
11. Enter your planned planting speed using Up/Down

arrow keys. Calibration mode will not accept a speed
higher than 10 mph. Press Function key to advance
to next window.

Refer to Figure 78
12. Enter the amount of seed you want to measure. For

volumetric metering, this should be at least

1

4

of a

pound. For singulated metering, at least 100 seeds
should be selected. Press Function key to advance
to next window.

Refer to Figure 79
13. The cab console informs you of the length of time

that the drive will be operating, in order to meter the
amount of seed you have requested, at the
calibration number, drill width, and number of rows
you have selected. Press Function key to advance to
next window.

Figure 77

Cal. Mode Speed

22721

Figure 78

Cal. Mode Seed Target

22722

Figure 79

Cal. Mode Time Window

22723