72
1510HDP/2010HDP/2510HDP
Great Plains Manufacturing, Inc.
118-245M
2013-10-21
Refer to Figure 77
11. Enter your planned planting speed using Up/Down
arrow keys. Calibration mode will not accept a speed
higher than 10 mph. Press Function key to advance
to next window.
Refer to Figure 78
12. Enter the amount of seed you want to measure. For
volumetric metering, this should be at least
1
⁄
4
of a
pound. For singulated metering, at least 100 seeds
should be selected. Press Function key to advance
to next window.
Refer to Figure 79
13. The cab console informs you of the length of time
that the drive will be operating, in order to meter the
amount of seed you have requested, at the
calibration number, drill width, and number of rows
you have selected. Press Function key to advance to
next window.
Figure 77
Cal. Mode Speed
22721
Figure 78
Cal. Mode Seed Target
22722
Figure 79
Cal. Mode Time Window