Options setup, Acremeter installation, Seed monitor cab module – Great Plains 2510HDP Operator Manual User Manual

Page 26: Speed sensor installation

Advertising
background image

22

1510HDP/2010HDP/2510HDP

Table of Contents

Index

Great Plains Manufacturing, Inc.

118-245M

Table of Contents

Index

2013-10-21

Options Setup

Prior to first use, install any optional equipment that was
not factory- or dealer-installed.

Even if factory- or dealer-installed, some items may need
setup for your specific requirements.

Acremeter Installation

Refer to Figure 19
The acremeter

may be supplied from the factory in a

separate carton, to minimize risk of shipping damage.
Check to see if it has already been installed by your
dealer. It is located on the outside end of the upper wheel
arm pivot shaft

. It may be installed on either the left or

right gauge wheel.

If not already installed:

1.

Slide the spacer tube

onto the shaft.

2.

Slide the shaft adaptor

onto the shaft, aligning its

cross-pin hole with the hole in the shaft.

3.

Insert the clevis pin

through the adaptor and shaft

and secure with cotter pin

.

4.

Screw the threaded end of the meter

into the

1

2

-20 tapped hole in the adaptor

.

Tighten the threaded end only enough to prevent it from
working loose from normal vibration. In use, there is no
torque or tension that might tend to unscrew it.

See “Acremeter Operation” on page 30.

Seed Monitor Cab Module

If your drill has the optional seed monitor, the cab
module may already have been installed by your dealer.
If not, consult the installation instructions included with
the option kit, and mount the module in a convenient
location.

If the cab is particularly noisy, or the operator customarily
wears a noise-cancelling headset, the alarms may not be
audible. Mount the module where the controls and status
indicators are visible during planting operations.

See the separate DICKEY-john manual for initial setup of
the seed monitor.

Speed Sensor Installation

The optional seed monitor requires a speed input in
order to determine seeding rate. The sensor is ordered
separately, and may be a magnetic pickup, or a radar,
mounted on the drill or on the tractor. Consult the
documentation supplied with the sensor.

Figure 19

Acremeter Installation

27220

4

1

3

6

5

2

1

2

3

4

5

6

1

4

Figure 20

Seed Monitor Cab Module

27390

Advertising