Hydraulic Drive Operation

73

2013-10-21

Table of Contents

Index

118-245M

Refer to Figure 80
14. If the screen reads TIME TOO LOW, or TIME TOO

HIGH, you will need to change the amount of seed
that you will count or measure. For calibration
accuracy, the Controller firmware will not allow you to
calibrate at settings that would result in the drive
rotating for less than 4 seconds, or more that 255
seconds. Press Function key to advance to next
window.

Refer to Figure 81
15. The drive is about to operate, meaning there is a

danger of entanglement if anyone is in the drive
area.

Be sure to verify that no one is near the drive area before
advancing to the next step.

Refer to Figure 81
16. Only after you have verified the drive area is clear,

press the up arrow key to initiate calibration mode. If
drive area isn’t clear, press Down arrow key to exit
calibration mode.

Refer to Figure 82
17. Continuing to verify that the drive area is clear, press

the Engage key to start drive rotation. Pressing
Function key will exit calibration mode.

Figure 80

Cal. Mode Time Limit Error

22782

Figure 81

Cal. Mode Clear Area

22724

Figure 82

Cal. Mode Initiate Motion

22726