Console Functions

Refer to Figure 70
The use of each key is as follows:

• On/VR key-turns drive system on. Press twice for VR

mode. Note: Engage key must also be pressed to start
drive operation.

• Off key: used to shut off Console.

• Function key: used in calibration mode and to program

Console for VR recipes.

• Up/down arrow keys: used to change rates manually,

to set calibration numbers, and VR controller options.

• Engage key: press to start drive.

Note: Drive will not run unless light above key is illuminat-

ed.

Note: Figure 70 shows Main Operating Screen in manual

mode.

Calibration

Refer to Figure 71
1.

Turn on Controller Console by pressing On/VR key.
Green light above On/VR key will illuminate when
power is on. Adjust desired planting rate by using the
Up/Down arrow keys to change the Set rate.

2.

Set the desired Rate by using the Up/Down arrow
keys.

Refer to Figure 72
3.

Press Function key until Calibration Number window
appears.

4.

Select drive calibration number based on row
spacing and metering wheel, from chart. See
Hydraulic Drive Calibration” on page 80.

5.

Use Up/Down arrow keys to set Calibration number.

Figure 70

Controller Key Functions

22710

Figure 71

Initiate Calibration

22715

Figure 72

Calibration Number Prompt