Dell PowerEdge VRTX User Manual

Page 105

Advertising
background image

Error Code

Message Information

Details

Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and
does not support FlexAddress.

Action

Update BIOS, BMC/iDRAC, LOM, and PCIe mezzanine card firmware.
If the issue persists, see

Getting Help

.

PCI3004

Message

Device option ROM on PCIe mezzanine card <

number

> failed to

support Link Tuning or FlexAddress.

Details

Either the BIOS, BMC/iDRAC, or PCIe mezzanine card firmware is out
of date and does not support FlexAddress.

Action

Update BIOS, BMC/iDRAC, and PCIe mezzanine card firmware. If the
issue persists, see

Getting Help

.

PCI3006

Message

Failed to get Link Tuning or FlexAddress data from iDRAC.

Details

Either the BIOS or BMC/iDRAC firmware is out of date and does not
support FlexAddress.

Action

Update BIOS, and BMC/iDRAC firmware. If the issue persists, see

Getting Help

.

PCI3008

Message

A non-fatal PCIe error detected on a component at bus
<

bus

>device<

device

>function <

func

>.

Details

System performance may be degraded.

Action

Cycle input power, update component drivers, remove and reinstall
the device at the next service window.

PCI3010

Message

A non-fatal IO error detected on a component at bus
<

bus

>device<

device

>function <

func

>.

Details

System performance may be degraded.

Action

Cycle input power, update component drivers, remove and reinstall
the device at the next service window.

PCI3012

Message

The QuickPath Interconnect (QPI) width degraded.

Details

System performance may be degraded. The bus is not operating at
maximum speed or width.

Action

Reset the system, if the problem persists reinstall processors.

PCI3014

Message

A non-fatal PCIe error detected on a component at slot <

number

>.

Details

System performance may be degraded.

105

Advertising