Dell PowerEdge VRTX User Manual

Page 129

Advertising
background image

Error Code

Message Information

LCD Message

System inlet <

name

> temperature is outside of range. Check Fans.

Details

Ambient air temperature is too warm or one or more fans may have
failed.

Action

Check the system operating environment and review event log for fan
failures.

TMP0122

Message

The system inlet temperature is outside of range.

LCD Message

System inlet <

name

> temperature is outside of range. Check Fans.

Details

Ambient air temperature is too warm or cool.

Action

Check the system operating environment and review event log for fan
failures.

TMP0100

Message

Disk drive bay temperature is less than the lower warning threshold.

Details

Ambient air temperature is too cool.

Action

Check the system operating environment.

TMP0104

Message

Disk drive bay temperature is less than the lower critical threshold.

LCD Message

Disk drive bay temperature is outside of range. Check Fans.

Details

Ambient air temperature is too cool.

Action

Check the system operating environment.

TMP0126

Message

Disk drive bay temperature is greater than the upper warning
threshold.

LCD Message

Disk drive bay temperature is outside of range. Check Fans.

Details

Ambient air temperature is too warm or one or more fans may have
failed.

Action

Check the system operating environment and review event log for fan
failures.

TMP0128

Message

Disk drive bay temperature is outside of the allowable range.

LCD Message

Disk drive bay temperature is outside of range. Check Fans.

Details

Ambient air temperature is too warm or cool.

Action

Check the system operating environment and review event log for fan
failures.

129

Advertising